The rest of the jug and a gallon of hot water.
Drain pvc from ac in attic.
Check that the condensation is being removed.
Imc 307 2 5 states that the condensate assembly must be installed in such a way that the drain line can be cleared of blockages and maintained without cutting the drain.
Find the condensate drain line and drain line access point.
Locating your ac drain line.
Once you find the pvc.
Deep with hemmed edge.
Most but not all ac units will have an easy to locate access point to the drain line.
The condensation drip from the condenser is carried from the inside to the outside.
Buy a jug of hair and grease declogger for about 12 bucks.
Most ac drain lines are pvc pipes cemented other with some sort of clean out.
If you can separate the cleanout from the ac or block the path of water back to the ac drain pan you can insert the.
Here in humid washington dc i ve seen pvc bead and sweat in attics.
Rigging a jig to unclog your pan drain of an attic type ac unit.
Go to the main line and pour half of the jug in the line.
Use the measuring tape to measure and cut the pipe lengths to run from the primary and secondary connections on the drain pan to the draining points outside.
Galvanized steel construction with attached pvc fitting.
The line is a pvc pipe that runs from the condenser inside your house to the outside next to the compressor.
Sand down any rough edges with sandpaper or a file.
About a half gallon.
Wait about an hour and pour hot water down the drain.
Drain pans collect condensation to prevent leakage in walls and ceilings due to moisture run off from primary ac pans.
Check the condensation line.
When a drain line is pvc the imc dictates that it should be supported every 4 when horizontal while maintaining proper pitch and every 10 vertically.
But the next day do it again.
Drain line not included.
99 confident this will clear your line.
Locate under hvac unit and attach to 3 4 in.
Your air conditioner drain line also known as the condensate drain is a small dripping line on the outside of your house where your air conditioning unit resides.
Look for white pvc pipe around 3 4 inch 1 9 cm in diameter coming out of your ac system s indoor unit.
This drain plays an important role in removing any condensation that your air conditioner s evaporator coil may produce.
Use a hacksaw on pvc or a pipe cutter on metal materials.
It s usually located outdoors next to the compressor.